XSite 400

Download Recent Update

Latest Version: 4.00.19 (Description)
Released On: Wednesday, May 15, 2024

Supplemental Files

The following DLL library file must be installed before running XSite 4.0 for the first time.

msmpisetup.exe (5.9 MB, Stand-alone, redistributable and SDK installers for Microsoft MPI)

User Guide

Download the XSite 4.0 User's Guide (PDF, 6 MB).

Known Issues

  • The maximum proppant concentration is still hardwired to 0.7. It should probably increased to 1.0
  • Need to take a closer look at proppant stress when the new conductivity curves (indexed by proppant concentration and stress) are used.
  • Perforated tunnels:
    • Simplified logic cluster volume calculation needs to take in consideration that the part of the perf. tunnel cylinder is already taken into consideration by the borehole volume;
    • Generalize the logic for viscosity transition allowing switch from power-law fluid and include power-law fluid and fluid transition in the simplified logic; and
    • resetClusterOnNodes is called after a stage is inactivated; it probably should not to avoid premature connection of the active fractures with those connected with inactive clusters.
  • Export grid function is limited to infinite horizontal plane seams. Will added ability to specify export extent based on top and lower seam for minimum and maximum Z-coordinate and fractures location for X- and Y-coordinates.
XSite 4.00 64-bit Update

Software Update Revisions

Revision Date Description
19 May 15, 2024
  • Updated user's guide
  • Fixed importing fracman
  • Added limit range to save/restore
  • Fixed history locations for fluidjoints
  • Fixed joints getting deleted if global coordinates were used with a rotation
18 Apr 24, 2024
  • Fixed reset temperature to properly use springs instead of nodes
  • Fixed display histories when no cluster exists
  • Added exact location of history tp the output of batch and console
  • Fixed pressure initialization of matrix pressure
  • Fixed limit range of of fracman dfn import, now limits springs on initialization rather than when importing
  • Added reset temperature to batch, save restore needs to be fixed
17 Mar 22, 2024
  • Fixed crash when importing joints using dxf files
  • Removed broken example problems and fixed some
  • Fixed bug on sub-lattice zone initiation of joints
  • Added limit import range to import fracman DFN dialog
  • Fixed bug on sketch model when plotting boreholes with reference point and azimuth rotation
  • Added reset temperature to reset lattice, allowing temperature of segments to be set to fixed or to loose
16 Mar 5, 2024
  • Added heal microcracks to batch
  • Updated Enable Multistep to Enable Multistepping During Advection Simulation
  • Fixed crash on running mechanical with fluid inactive
  • Fixed calibration mode not cracking properly
15 Feb 21, 2024
  • Fixed micro cracks counter when exporting micro cracks
  • Added check box to batch and reset lattice to import only connected micro cracks when importing initial state
  • Added heal microcracks to reset lattice for removing cracks that don't have pipes connected
14 Feb 15, 2024
  • Fixed initial state not importing proppant concentration
13 Feb 2, 2024
  • Fixed prevent micro cracking check box not being saved on restore
  • Added micro crack counter to micro crack export when using a grid
  • Fixed batch depletion workflow dialog box
12 Jan 19, 2024
  • Added fast pore pressure import method for rectangular and uniform grids
  • Fixed crash on proppant concentration plot item and importing from fluid nodes file
11 Dec 12, 2023
  • Fixed license dialog version
  • Updated thermal example in example files
  • When exporting microcracks with a grid, empty Joint List will show as N/A
  • Fixed bug when checking for joint intersection resulting in an undefined joint intersection angle
  • Fixed bug not allowing initial state to be loaded
  • Updated reset lattice dialog
  • Fixed import bug for MC files
  • Fixed permeability bug for importing multiple fracman dfns
10 Nov 28, 2023
  • Minor GUI changes
  • Excavate now deletes fluid nodes, pipes and fluid joint from liner
09 Nov 16, 2023
  • Added maximum number of mech interactions to reset lattice and batch dialog
  • Removed option to run 10000 mechanical steps if relative volume balance is greater than 10%
  • Fixed pump schedule import dialog
08 Nov 6, 2023
  • Fixed cluster fluid node activation
  • Update thermal options text on solutions tab
  • Fluid cycle during thermal equilibrium runs with allow aperture change only on first cycle
7 Oct 4, 2023
  • Pipes are impermeable if both fluid elements are impermeable. Pore pressure changes are calculated for impermeable fluid elements.
  • Fixed cluster issue not getting activated properly
  • Update for intel oneAPI 2023
  • Missing labels in hfconfig.xml
  • Removed libfabric from linuxdeploy.bat
6 Sep 12, 2023
  • Building w/ CMake
  • Using Github for subversion control
  • Fixed issue with wrong fluidnodes being calculated in implicit logic
  • Only fluid elements inside the perf tunnel or completion wil be skipped on the implicit calculations
  • Fixed bitmap exporter
  • Fixed dialogs for borehole import and wellgeometry import
5 Jul 31, 2023
  • Fixed display of demo mode watermark.
  • Enhanced console license security.
4 Jul 20, 2023
  • Fixed UI bugs causing crashing.
  • Added heat advection multistepping.
3 Jul 11, 2023
  • Added variable to store matrix pressure.
  • Added security to console version.
2 Jun 13, 2023
  • Bug fix: Fixed Bitmap export crash.
1 Jun 12, 2023
  • Updated from XSite 3.0.69.
  • Bug fix: the Matrix checkbox in the Features/Fluid tab will be unchecked after reloading a file following fluid injection.
  • Bug fixed: code was crashing during post-processing execution when exporting MC using grid file.
  • Bug fix: code was crashing when recreating fluid nodes when adaptive resolution was being applied to the model.
  • Bug fix: code was crashing stop simulation before it finishes and click on Reset Model. Reset the batch and when you execute it again.
  • Added checkbox on Features/Sink tab that will allow to activate the sink when the defined pressure is reached.
XSite Software Downloads

Latest News
  • Wishing you and yours Happy Holidays Wishing you and yours Happy Holidays...
    Read More
  • Now Available from ITASCA: Innovative Machine Learning Tool for FLAC3D/FLAC2D V9.2 Experience the Future of Geotechnical Modeling with ITASCA Software V9.2: Introducing Machine Learning Models...
    Read More
  • Experience the Future of Geotechnical Modeling with ITASCA Software V9.2 Experience the Future of Geotechnical Modeling with ITASCA Software V9.2: Introducing Machine Learning Models and...
    Read More